How to operate baskets at high altitude safely?

News Related Keywords: No tags.

High altitude operation safety rules

1. The high altitude operation blue must be repaired and maintained by qualified personnel with special operations.

2. Hanging blue construction requires at least two people to operate at the same time. Persons entering Hanging Blue must wear safety belts and wear safety helmets.

3 , the working platform is strictly prohibited overload operation. Type 630 Hanging Blue Load 630 kg (including the weight of the crew). The load in the platform should be evenly distributed.

4. When the working platform is tilted, it should be adjusted to the level in time. The operator should pay attention to the hanging blue operation at any time and eliminate hidden accidents in time.

5. When the working platform rises, keep the safety wire rope vertical.

6. In normal operation, it is forbidden to use manual brakes. Manual safety locks are strictly prohibited. Lifting machines, safety locks, and electrical boxes are strictly prohibited.

7. The safety steel wire rope shall not be twisted or bent, nor be stained with oil or sundries; the working steel wire rope shall not be tortuous, and must not be stained with mortar or sundries. The phenomenon of broken wire, disordered strands, cracking, abrasion, corrosion, etc. must be found and must be in accordance with the requirements of the regulations. Replace it.

8. During the construction of hanging blue, the lessee shall wrap the vertical poles and horizontal railings of the hanging blue against the wall with a thick sponge or a soft packing to avoid damage to the building and hanging blue.

9. It is forbidden to disassemble hoisting machines, safety locks, wire ropes, etc. when working platforms are suspended in the air. When a fault must be removed and replaced, it must be carried out by professionals on the premise of the implementation of safety measures. After the replacement, the premise of ensuring safety will be lowered to the ground to conduct a comprehensive inspection, and if everything is normal, it can continue to work.

10 , hanging blue should not be in acid, alkali and other corrosive environments and work at night, banned in thunderstorms, and six winds above the environment.

11. When an emergency such as a wire rope breakage occurs during work, the operator should be calm and calm, and withdraw from the work platform while ensuring safety, and be handled by professionals.

12. Each time before use, safety inspection must be performed according to the use requirements. The safety lock must be sent to the professional manufacturer for overhaul after exceeding the calibration period. Non-professionals must not disassemble the security lock without permission.

13. The Hang Blue Tenant shall carry out morning, middle and evening safety inspections of the suspension mechanism (including counterweights, wire ropes, rope clamps, bolts, etc.) and hanging blue work platforms on a daily basis. Employees on site should do daily security checks five times a day.

14. When hanging blue is to be shifted, it must be conducted under the guidance of a professional and must be checked by qualified personnel before it can continue to be used.

15. After each construction (including noon break), the hanging blue must be lowered to 30CM ~50CM from the ground . During the hanging blue work, the extra long wire rope (including work and safety wire rope) should be rolled up and off the ground. 15CM suspension, and then the weight is properly suspended.

16 , if the hanging blue can not fall directly to the normal, the lessee should do a good job in advance blue hanging with the safety measures to provide a safe and reliable blue landing.

17. After the use of hanging blue is over, the operator should turn off the power switch, lock the electrical box, clear the wire rope and all parts of the mud, and make rainproof measures (including suspending the construction halfway) for the lift and safety lock electrical boxes. Rainwater enters hoists, safety locks and electrical boxes.

18 , hanging blue shall not be used as a vertical transport tool.

19 , hanging blue in the use of the site within the 10M range shall not have high-voltage lines or high-voltage devices.

20. Warning signs should be set at the ground 5M below the scope of hanging blue .

Emergency safety measures

1. When there is a sudden power outage during work, the power should be turned off first to prevent accidents during calls and to temporarily withdraw from the work platform while ensuring security.

2. Handling after sudden breakage during work: When the hanging blue is running in the air, a sudden break of the working steel wire rope or failure of the hoisting machine should be fixed to the working wire rope with a short steel wire rope under the condition that the safety lock is normally locked. The upper end is then connected to the work platform and tightened. If the working wire rope cannot ensure safety, the short steel wire rope should be fastened to the safety wire rope before the hoist replacement and overhaul work.

This article is edited and compiled by China Rescue Equipment Network. Please indicate the link.

Stepper Motor Peristaltic Pump

The stepper motor Peristaltic Pump can be used alone with the control program developed by our company, or it can be used with the customer's own PLC control program.

The integrated circuit board specially designed by our electronic engineers can be used with NEMA23 stepper motors, and try a variety of pump head pump tubes at the same time. Support the function customization of Modbus protocol and analog control. The size of the circuit board is as large as the palm of the hand, but its functions are comparable to the digital peristaltic pumps on the market. UCP series peristaltic pumps have compact structure, small volume, powerful functions and high precision. It is suitable for various medical equipment, analytical instruments, packaging machinery, etc.